This error occurs when the pump's physical safety is triggered due to a lack of water, causing only CO₂ to be dispensed.
Open the lower door of the station.
Open Maintenance Menu on the station's touchscreen.
Disconnect the cooling unit cable from the internal socket.
Reconnect this cable.
Open the "Tests" section, then perform a 17oz / 500ml CO₂ test.
Wait for pump to stop. (approx. 45 seconds)
Close the station's lower door and exit the menu.