Relocation
Last updated
Last updated
Open the Maintenance Menu on the station's touchscreen, then access the Products tab.
Keep this mixture of water and glycol for future re-installation.
Unplug the cooling unit from the internal power outlet.
Move the tray under the cooling basin slightly forward.
Remove the temperature sensor from the basin, and its base if necessary.
Remove the pipe and place it in a container of at least 16 liters (4.2gal).
Reconnect the cooling unit to the internal power outlet.
Wait for the cooling basin to empty into your container.
Once the basin is empty, unplug the cooling unit from the internal power outlet.
Put the pipe, temperature sensor and tray back in place.
Access the Valves tab of the Maintenance Menu on the touchscreen.
Use the Valve Test function to empty the pipe of still water. (2x 1 liter)
Use the Valve Test function to empty the pipe of sparkling water. (4x 500ml)
If the station is likely to be exposed to temperatures below 0°C (32°F), remove the filter (see Replace the Filter) and keep it indoors.
Turn the filter valve to the closed position.
To redisplay the interactive setup menu, assign the station to a new customer or reset the beverage counter, contact .